$55.60
Travels with refrigerant, not oil: Ensures full‑circuit coverage, avoids oil‑borne deposits, and protects metering devices. Proven Results: Millions of leaks sealed since 1999 and still going! Atomizes on injection; fully compressible: Preserves compressor performance and system efficiency. Reacts...
Orders ship within 5 to 10 business days.
- Travels with refrigerant, not oil: Ensures full‑circuit coverage, avoids oil‑borne deposits, and protects metering devices.
- Proven Results: Millions of leaks sealed since 1999 and still going!
- Atomizes on injection; fully compressible: Preserves compressor performance and system efficiency.
- Reacts only at real leak sites: Non-reactive inside the system; activates with pressure change, moisture, and air to seal quickly and durably. Polymer-Free technology.
- Fast, durable sealing: Targets micro-leaks to reduce refrigerant loss, improve reliability, and minimize repeat service calls.
- Broadest size range in the industry: From mini appliance systems to 60‑ton commercial and industrial units.
- Wide refrigerant compatibility: Works with all refrigerants used in HVACR except ammonia systems. A2L compatible.
- Pro‑grade convenience: Designed for efficient field installation and rapid return-to-service.
-
Prepare System & Ports:
- Ensure system is running with the compressor engaged
- Important: If system is a heat pump, set it to cooling before proceeding.
- Identify both the low-side (suction) and high-side (liquid) service ports.
-
Check Injector Compatibility
- Condition: Preform only if your vavle core is too deep to be engaged by the Xpress Inject tube.
- Action: To fix, turn the depressor on your Xpress Inject counterclockwise (max 1 turn) until you confirm it properly engages the system’s valve core.
- Ensure system is running with the compressor engaged
- Connect Xpress Inject: LOOSELY Connect the Xpress Inject tube (containing the sealant) to the low-side service port. Will complete connection after purge of manifold hoses.
-
Prepare Manifold:
- Ensure both the high-side (red) and low-side (blue) valves on your manifold gauge set are COMPLETELY CLOSED.
- Attach your high-pressure (red) manifold hose to the system’s high-side (liquid) service port.
- Attach your low-pressure (blue) manifold hose to the XPRESS Inject tube connected at the low-side service port.
-
Purge Manifold Hose:
- Quickly crack open and close the high-side (red) manifold valve to allow a small amount of high-pressure refrigerant to purge air out of the low-side (blue) hose.
- Then, close the high-side (red) manifold valve.
- Securely tighten the Xpress Inject onto the low side service port.
-
Inject XPRESS SEAL:
- Slowly open the high-side (red) valve on your manifold.
- Then, slowly open the low-side (blue) manifold valve. High-pressure refrigerant from the system’s high-side will flow through your manifold and push the XPRESS SEAL from the tube into the system’s low side.
- Watch the XPRESS Inject tube: the system’s suction pressure will draw the sealant into the system. Continue until the tube is clear of sealant.
-
Close & Disconnect
- Once the XPRESS Inject tube is empty and clear, close the low-side (blue) manifold valve.
- Close the high-side (red) manifold valve.
- Disconnect your manifold hose from the XPRESS Inject.
- Disconnect the XPRESS Inject from the service port. Discard or recycle the empty XPRESS Inject tube responsibly.
-
Finalize: Install the service port cap securely.
- Let system run for at least 1 hour to ensure distribution of sealant throughout the system.